Photovoltaic facility profile dabo over Heidenheim an der Brenz

dabo
dabo

dabo

CountryGermany Germany
StateBaden-Württemberg
AreaStuttgart
Administrative districtHDH
Postal code89520
PlaceHeidenheim an der Brenz
Overall performance10.965 kWp
Update05.08.2020 03:06
Data importAutomatically

User profile

offline
dabo over Germany Germany Last login 19.07.2019 Member since 06.04.2007 1 Systems
0 Awards
Start of operations2007
Affection50°
Achievement10.965 kWp
tracingstationary
Orientation170°
Installation engineer
moduls 51 x SANYO HIP-215 NHE5
Power inverter 3 x SMA Solar Technology SB 4000TL
DataloggerSolare Datensysteme - SolarLog400e
Building costs0 €
Line diagram line chart bar chart

Specific revenues kWh/kWp.

days 06.07.07.07.08.07.09.07.10.07.11.07.12.07.13.07.14.07.15.07.16.07. sum
proceeds5,744,054,974,955,814,194,935,585,001,721,0547,99
days17.07.18.07.19.07.20.07.21.07.22.07.23.07.24.07.25.07.26.07.27.07.sum
proceeds3,774,504,155,245,355,175,764,185,153,675,55100,48
days28.07.29.07.30.07.31.07.01.08.02.08.03.08.04.08.05.08.sum
proceeds5,345,785,845,685,481,111,341,530,00132,58
Line diagram line chart bar chart

Specific revenues kWh/kWp.

sum
dabo124,3098,2571,7527,4840,6142,1963,22109,10153,32125,57105,49146,369,471117,11
Baden-Württemberg125,2897,8860,0130,3137,6436,5149,3096,31141,57136,41116,00144,2810,881082,38
Germany120,8292,3657,0525,8027,4227,5443,41100,84149,49138,06121,44133,6213,261051,11
Line diagram line chart bar chart

Specific revenues kWh/kWp.

20072008200920102011201220132014201520162017201820192020 sum
dabo743,591076,511021,80958,721127,531110,20931,14986,861070,101006,721066,101094,401072,23754,7214020,62
Baden-Württemberg1052,851032,621025,02953,051129,151085,31945,631022,811070,801002,061045,711086,041029,77742,4214223,24
Germany992,52980,46997,30945,611057,65992,20915,89836,43870,80810,60793,55623,391008,32729,9512554,67
Line diagram line chart bar chart normal accumulated

Specific revenues kWh/kWp.

Year JanFebMarAprMayJunJulAugSepOctNovDec sum
20070,0015,1854,0088,8268,7362,82113,91113,0089,6475,2735,5026,72743,59
200842,2898,4487,2791,58137,67127,57133,06129,9586,6564,8251,9225,301076,51
200949,1543,7366,24124,57125,31128,68127,11137,07102,6456,6237,6623,021021,80
201018,7645,29109,85127,8183,87112,14136,57100,86103,0576,3332,0612,13958,72
201126,2046,45120,89149,57148,03110,27117,52135,25119,7592,9439,3421,321127,53
201236,4370,13113,13103,72145,30123,20128,91141,06115,5474,1530,8827,751110,20
201317,6329,6983,9991,8793,72119,58147,19127,9996,0763,0528,6531,71931,14
201428,6859,98124,60108,02122,49137,47117,56108,4979,2559,4123,8517,06986,86
201529,4650,05104,69141,94114,67117,08144,84133,7589,7048,1754,0741,681070,10
201634,1939,7792,8497,63122,03108,90125,01147,77115,6459,8333,5729,541006,72
201748,6552,90110,39109,90126,37142,82125,06126,0690,4279,9129,2224,401066,10
201829,0760,9277,96141,64137,67123,58137,38126,77118,8386,1835,1219,281094,40
201918,9086,3999,87117,34111,13139,39136,82124,3098,2571,7527,4840,611072,23
202042,1963,22109,10153,32125,57105,49146,369,470,000,000,000,00754,72
32,4354,4496,77117,70118,75118,50131,24118,70100,4269,8835,3326,19
31,6256,9899,31117,13122,36124,22131,42128,28101,3269,4335,3226,15

specific revenues accumulated [kWh/kWp]

Year JanFebMarAprMayJunJulAugSepOctNovDec
20070,0015,1869,18158,00226,73289,55403,46516,46606,10681,37716,87743,59
200842,28140,72227,99319,57457,24584,81717,87847,82934,47999,291051,211076,51
200949,1592,88159,12283,69409,00537,68664,79801,86904,50961,12998,781021,80
201018,7664,05173,90301,71385,58497,72634,29735,15838,20914,53946,59958,72
201126,2072,65193,54343,11491,14601,41718,93854,18973,931066,871106,211127,53
201236,43106,56219,69323,41468,71591,91720,82861,88977,421051,571082,451110,20
201317,6347,32131,31223,18316,90436,48583,67711,66807,73870,78899,43931,14
201428,6888,66213,26321,28443,77581,24698,80807,29886,54945,95969,80986,86
201529,4679,51184,20326,14440,81557,89702,73836,48926,18974,351028,421070,10
201634,1973,96166,80264,43386,46495,36620,37768,14883,78943,61977,181006,72
201748,65101,55211,94321,84448,21591,03716,09842,15932,571012,481041,701066,10
201829,0789,99167,95309,59447,26570,84708,22834,99953,821040,001075,121094,40
201918,90105,29205,16322,50433,63573,02709,84834,14932,391004,141031,621072,23
202042,19105,41214,51367,83493,40598,89745,25754,72754,72754,72754,72754,72
32,4384,55181,33299,02417,77536,27667,51786,21879,45944,34977,151001,47
31,6288,60187,91305,04427,39551,62683,04811,31912,63982,061017,381043,53
Durchschnitts-Werte der Monate mit eingetragenen Ertragsdaten Durchschnitts-Monatswerte aller vollständigen Jahre seit Inbetriebnahme
choose 1. User choose 2. User

06.02.2011 dabo

Ab 08.07.2007 wurde von 5,85 auf 11 kWp erweitert, die spezifischen Erträge (kWh/kWp) vor diesem Datum sind um 47% zu klein dargestellt continue reading

06.02.2011 dabo

01.03.2008 : 1. Wechselrichter defekt, nach Austausch 3 Tage später wieder in Betrieb; neue Firmware, leider Ertragsverluste bei kleinen Leistungen! 13.06.2008 : Alte WRs (3 x KACO 3501xi) entfernt, gegen 3 neue WRs (SMA SB4000TL-20) getauscht. continue reading